LC1 Overload Control Unit

tüm aşırı yük sistemleriyle uyumlu kontrol ünitesi

Analog outputs and optional RS232 digital output

Audible overload alarm system

otomatik düzeltme

Automatic compensation for mechanical drift

Measurement stabilization during cabin movement via Hold Input

  • 24-bit ADC for high-resolution measuremen  capability
  • Fixed-load calibration capability
  • Easy parameter adjustment with 3-button menu
  • 3 independently configurable relay outputs
  • 4-digit digital display
  • Compatible with all load cells via wide voltage input range
Technical Information
Accuracy
Linearity: %0.003
Temperature Deviation: ±5ppm/⁰C
A/D Converter: 24 Bit Delta-Sigma
Digital Filter: Smart window filter and high frequency filter
Readout Rate: 10 Hz
Load Cell
Supply Voltage5VDC
Analog Input Range± 40mV/V
Max. Load Cells8 pieces
Supply
Operating Voltage: 110-240VAC, 50/60Hz (24VAC/DC opt.)
Power Consumption: 4W Max. AC
Box
Size170x105x40mm
Weight0,23kg
Protection ClassIP20
Operating Temperature-20…+85℃
Inputs and Outputs
Load Cell Input: 2 screw terminals
Hold Input: 1 Piece 24…220V AC/DC
Relay Outputs: 4 pcs 3A, 125VAC, NC/NO
Analog Outputs: 0-10V and 4-20mA (12 Bit)
Digital Outputs: RS232 Ops.
Indicators
Digital Display: 7mm 4 digits
Led Indicator: 4 role active led
Audible Warning: 50dB, 1 Meter
CENTA Elevator Brand

LC1 Unidades De Control De Sistemas De Sobrecarga